EN  |  DESP

Products

EOL Products

PEG4SFPI6-GXX

Quad Port Fiber Gigabit SGMII SFP Ethernet PCI Express Server Adapter Intel® Based

This product has been discontinuedEOL Notification

Silicom’s Quad Port SGMII SFP Gigabit Ethernet PCI Express Server adapter is a PCI-Express X8 network interface card that contains four Gigabit SGMII SFP ports on a PCI-Express adapter.

Silicom’s Quad Port SGMII SFP Gigabit Ethernet PCI Express Server adapter is designed for Servers and high-end appliances. The adapter is designed for multi-core processors and optimized for virtualization.

Silicom’s Quad Port SGMII SFP Gigabit Ethernet PCI Express Server adapter enable fault-tolerant via teaming. Traffic from the failed port is routed through other members of the team. Silicom’s Quad Port SGMII SFP Gigabit Ethernet PCI Express Server adapter has an integrated hardware acceleration that performs TCP/UDP/IP checksum offload and TCP segmentation. The host processing offloads accelerators frees CPU for application processing.

Silicom’s Quad Port SGMII SFP Gigabit Ethernet PCI Express Server adapter is the ideal solution for implementing multiple network segments, mission-critical high-powered networking applications and environments within high performance servers.

Silicom’s Quad Port SGMII SFP Gigabit Ethernet PCI Express Server adapter is based on Intel 82576 Dual Port Gigabit Ethernet MAC+PHY of Intel Controller.

PEG4SFPI6-GXX

Quad Port Fiber Gigabit SGMII SFP Ethernet PCI Express Server Adapter Intel® Based

Performance Features:

  • 16 Transmit and Receive queues per port
  • Up to 16 queues of Receive Side Scaling (RSS) minimize CPU utilization across multiple processor systems
  • Support for 8 pools ofvirtual machine Device Queues ( VMDq) per port
  • Support Direct Cache Access ( DCA)
  • Support Intel I/O AT 2.0
  • TSO interleaving for reduced latency
  • UDP TSO
  • Minimized device I/O interrupts using MSI and MSI-
  • Offload of TCP / IP / UDP checksum calculation and TCP segmentation
  • SCTP receive and transmit checksum offload
  • Packet interrupt coalescing timers (packet timers) and absolute- delay interrupt timers for both transmit and receive operation

Fiber Fast/Gigabit Ethernet:

  • Support SFP transceivers with Built-in PHY supporting SGMII Interface:
  • Small Form Factor Pluggable (SFP) Cage for SFP LC connectors

Fiber Fast Ethernet:

  • Single Mode 100Base-LX10 Fiber Fast Ethernet with Built-in PHY supporting SGMII Interface
  • Small Form Factor Pluggable (SFP) Cage for SFP LC connectors

Fiber Fast/Gigabit Ethernet:

  • Support SFP Dual rate transceiver with Built-in PHY supporting SGMII Interface:
  • Multimode 1000Base-LX Fiber Gigabit Ethernet
  • Multimode 100Base-FX Fiber Fast Ethernet
  • Small Form Factor Pluggable (SFP) Cage for SFP LC connectors

Common Key Features:

  • Host Interface standard support PCI-Express Base Specification Revision 1.1
  • High performance, reliability, and low power use in Intel 82576 Dual integrated MAC + PHY and SGMII chip Controllers
  • Ultra deep, packet buffer per channel lowers CPU utilization
  • Hardware acceleration that can offload tasks from the host processor. The Controllers can offload TCP/UDP/IP checksum calculations and TCP segmentation
  • Hardware acceleration that can offload tasks from the host processor. The controllers can offload TCP/UDP/IP checksum calculations and TCP segmentation
  • Server class reliability, availability and performance features:
  • Link Aggregation and Load Balancing
    • Switch dependent: 802.3ad (LACP), Generic Trunking ( GEC / FEC)
    • Switch and NIC Independent
    • Failover
  • Priority queuing – 802.1p layer 2 priority encoding
  • Virtual LANs –802.1q VLAN tagging
  • Jumbo Frame (9.5KB)
  • 802.x flow control
  • PCI-SIG SR IOV (8 VF)
  • Multicast/ broadcast Packet replication
  • Statistics for SNMP MIB II, Ethernet like MIB, and Ethernet MIB (802.3z, Clause 30)
  • Supports Vital Product Data (VPD)
  • Integrated LinkSec security engines
  • Supports IEEE 1588
  • LEDs indicators for link/Activity Mode status

PEG4SFPI6-GXX

Quad Port Fiber Gigabit SGMII SFP Ethernet PCI Express Server Adapter Intel® Based

SFP Gigabit Ethernet Technical Specifications - (SFP) Adapters:

SFP (Small Form Factor Pluggable) supports: SGMII interfaces supports 100Base-X and 1000Base-X in order to connect with SFP to 100Base-X / 1000Base-X SFP transceivers
Data Transfer Rate:2000Mbit/s in full duplex mode per port (1000Base-X)
200Mbit/s in full duplex mode per port (100Base-X)
IEEE Standard / Network topology:Copper Gigabit Ethernet, 1000Base-T
Fiber Gigabit Ethernet, 1000Base-X
Fiber Fast Ethernet, 100Base-X

SFP Fast Gigabit Ethernet Technical Specifications - (SFP 100Base-LX10) Adapters:

SFP (Small Form Factor Pluggable) supports: SGMII interfaces supports 100Base-X in order to connect with SFP to 100Base-LX10 SFP transceivers
Data Transfer Rate:125Mbit/s per port (100Base-LX10)
IEEE Standard / Network topology:Fiber Fast Ethernet, 100Base-LX10 (1310nM)
Cables and Operating distance:Single mode fiber: 10Km maximum at MMF 9uM/125um
Optical Output Power:Minimum: -8 dBm
Optical Receive Sensitivity:Maximum: -31.5 dBm

SFP Gigabit Ethernet Technical Specifications (SFP 1000Base-LX , 100Base-FX) Adapters:

SFP (Small Form Factor Pluggable) supports: SGMII interfaces supports 100Base-X and 1000Base-X in order to connect with SFP to 100Base-FX and 1000Base-LX SFP transceivers
Data Transfer Rate:2000Mbit/s in full duplex mode per port (1000Base-LX)
200Mbit/s in full duplex mode per port (100Base-FX)
IEEE Standard / Network topology:Fiber Gigabit Ethernet, 1000Base-LX (1310nM)
Fiber Fast Ethernet, 100Base-FX (1310nM)
Cables and Operating distance:Multimode fiber:
2000m maximum at MMF 62.5/125um and 50/125uM (100Base-FX)
550m maximum at MMF 62.5/125um and 50/125uM (1000Base-LX)
Optical Output Power:Typical: -8.58 dBm
Minimum: -9.5 dBm
Optical Receive Sensitivity:Typical: -23.85 dBm
Maximum: -19 dBm

Operating Systems Support

Operating system support: Windows
Linux
FreeBSD
VMware

General Technical Specifications

Interface Standard:PCI-Express Base Specification Revision 1.1
Board Size: 167.64mm x 74.5mm (6.6”X2.935”)
PCI Express Card Type:X8 Lane
PCI Express Voltage:+12V +- 8%
PCI Connector: Gold Finger: X8
Controller: Intel 82576EB
Holder:Metal Bracket: Full Height
I/O:Small Form Factor Pluggable (SFP) Cage located on edge of the board
Weight:120gr (4.233 oz)
Power Consumption:5.76 W, 0.48 A at 12V: Typical, without SFP transceiver
Operating Temperature: 0°C – 50°C (32°F - 122°F)
Storage: -20°C–65°C (-4°F–149°F)
EMC Certifications: FCC Part 15, Subpart B Class B
Conducted Emissions
Radiated Emissions
CE EN 55022: 1998 Class B Amendments A1: 2000; A2: 2003
Conducted Emissions
Radiated Emissions
CE EN 55024: 1998 Amendments A1: 2000; A2: 2003
Immunity for ITE Amendment A1: 2001
CE EN 61000-3-2 2000, Class A
Harmonic Current Emissions
CE EN 61000 3-3 1995, Amendment A1: 2001
Voltage Fluctuations and Flicker
CE IEC 6100-4-2: 1995
ESD Air Discharge 8kV. Contact Discharge 4kV.
CE IEC 6100-4-3:1995
Radiated Immunity (80-1000Mhz), 3V/m 80% A.M. by 1kHz
CE IEC 6100-4-4:1995
EFT/B: Immunity to electrical fast transients 1kV Power
Leads, 0.5Kv Signals Leads
CE IEC 6100-4-5:1995
Immunity to conductive surges COM Mode; 2kV,
Dif. Mode 1kV
CE IEC 6100-4-6:1996
Conducted immunity (0.15-80 MHz) 3VRMS 80% A.M.
By 1kHz
CE IEC 6100-4-11:1994
Voltage Dips and Short Interruptions
V reduc >95%, 30% >95% Duration 0.5per, 25per, 250per

LEDs

LEDs:(2) LEDs per port
Left LED: Link/Act :
Turns on link (Green),
Blinks on activity (Green)
Right LED : Link Speed:
Turns on Yellow 1G Link.
Turns on Green 100M Link (optional for SGMII mode)
LEDs location:LEDs are located on the PCB, visible via holes in the metal bracket. Each Green Link/Act and Bi-color Link Speed LEDs are located above their own SFP connector port by light pipes.
Connectors:Small Form Factor Pluggable (SFP) Cage

PEG4SFPI6-GXX

Quad Port Fiber Gigabit SGMII SFP Ethernet PCI Express Server Adapter Intel® Based

P/N

Description

Notes

PEG4SFPI6-GXX-ROHSQuad Port Fiber SGMII SFP Gigabit Ethernet PCI Express Server AdapterRoHS Compliant, X8, SGMII support, based on Intel 82576EB, PCI-E
PEG4SFPI6-GLX10S-ROHSQuad Port Fiber (LX10) SGMII SFP Fast Ethernet PCI Express Server AdapterSupport GMMII SMF, 100Base-LX, based on Intel 82576EB, PCI-E X8, RoHS Compliant
PEG4SFPI6-GFLXM-ROHSQuad Port Fiber (FX/LX) SGMII SFP Gigabit Ethernet PCI Express Server AdapterSupport GMII MMF (62.5u/50uM), 100Base-FX and 1000Base-LX, based on Intel 82576EB, PCI-E X8, RoHS Compliant

 

1V1

FacebookTwitterLinkedIn
YouTube Channel