EOL Products
PEG2BPFI
Dual Port Fiber Gigabit Ethernet PCI Express Bypass Server Adapter Intel® Based
This product has been discontinued – EOL Notification
Silicom Gigabit Ethernet Bypass servers adapter are PCI-Express X4 network interface cards that contains two Gigabit ports on one PCI-E adapter.
Silicom’s Gigabit Ethernet Bypass nics are designed with optical or copper bypass circuitry in order to provide maximum up time for the network.
Silicom’s Gigabit Ethernet Bypass server adapters can Bypass its Ethernet ports on a host system failure, power off, or upon software request. In Bypass mode, the connections of the Ethernet network ports are disconnected from the interfaces and switched over to the other port to create a crossed connection loop-back between the Ethernet ports.
Hence, in bypass mode all packets received from one port are transmitted to other port and vice versa. This feature enables to bypass a failed system and provides maximum up time for the network. Silicom’s Gigabit Ethernet Bypass server adapters include an on board WDT (Watch Dog Timer) controller.
The adapter’s software drivers or software application can write commands to the on board WDT controller. The adapter’s software drivers, WDT controller and the Bypass circuitry provide an interface that control and manage the mode of the adapter.
Silicom Gigabit Ethernet Bypass server adapters have an integrated hardware acceleration that performs TCP/UDP/IP checksum offload and TCP segmentation. The host processing offloads accelerators frees CPU for application processing.
Silicom’s PEBPI-Series are adapters are based on Intel 82571 Dual port Gigabit Ethernet MAC+PHY of Intel Controller.
PEG2BPFI
Dual Port Fiber Gigabit Ethernet PCI Express Bypass Server Adapter Intel® Based
Bypass:
- Bypass Ethernet ports on Power Fail, System Hangs or Software Application Hangs
- Software programmable Bypass or Normal Mode
- On Board Watch Dog Timer (WDT) Controller
- Software programmable time out interval
- Software Programmable WDT Enable / Disable counter
- Software programmable Bypass Capability Enable / Disable
- Programmable state (Bypass mode or Normal mode) at Power up
- Emulates standard NIC
- Independent Bypass operation in every two ports
Fiber Gigabit Ethernet 1000Base-SX:
- Independently Fiber Gigabit Ethernet channel/s support Gigabit Ethernet 1000Base-SX
- Small Form Factor (SFF) LC Connectors
Fiber Gigabit Ethernet 1000Base-LX:
- Independently Fiber Gigabit Ethernet channel/s support Gigabit Ethernet 1000Base-LX
- Small Form Factor (SFF) LC Connectors
Common Key features:
- Host Interface standard support:
- Host Interface PCI-Express 4X Lane (Version 1.0a)
- High performance, reliability, and low power use in Intel 82571 dual integrated MAC + PHY and SERDES chip controller
- Ultra deep packet buffer per channel lowers CPU utilization
- Hardware acceleration that can offload tasks from the host processor. The controllers can offload TCP/UDP/IP checksum calculations and TCP segmentation
- Priority queuing – 802.1p layer 2 priority encoding
- Virtual LANs –802.1q VLAN tagging
- Jumbo Frame (9KB)
- 802.x flow control
- Statistics for SNMP
- LEDs indicators for link/Activity/Bypass Mode status
PEG2BPFI
Dual Port Fiber Gigabit Ethernet PCI Express Bypass Server Adapter Intel® Based
Bypass Specifications | |
WDT Interval (Software Programmable): | 3,276,800 mSec (3,276.8 Sec): Maximum 100 mSec ( 0.1 Sec) : Minimum WDT Interval = (2^wdt_interval_parameter)*(0.1) sec. wdt_interval_parameter: { Valid Range: 0-15} |
Fiber Gigabit Ethernet Technical Specifications - (1000Base-SX) Adapters: | |
IEEE Standard / Network topology: | Fiber Gigabit Ethernet, 1000Base-SX (850nM) |
Data Transfer Rate: | 2000Mbit/s in full duplex mode per port |
Cables and Operating distance: | Multimode fiber: 137m maximum at 62.5 um ** ** PXG2BPFI Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3 standard |
Optical Output Power: | Normal Mode (Bypass Off): Typical: -6.8 dBm (TX –Switch Norma – Fiber – LC/LC) Minimum: -10.9 dBm |
Optical Receive Sensitivity: | Normal Mode (Bypass Off) Typical: -19.7 dBm Maximum: -15.6 dBm |
Insertion Loss: | Bypass Mode: Insertion loss (Optical Power attenuation between TX to RX) Typical: 0.79 dB (From RX to TX) Maximum 1.9 dB |
Fiber Gigabit Ethernet Technical Specifications -(1000Base-LX) Adapters: | |
IEEE Standard / Network topology: | Fiber Gigabit Ethernet, 1000Base-LX (1310nM) |
Data Transfer Rate: | 2000Mbit/s in full duplex mode per port |
Cables and Operating distance: | Single-Mode fiber: 2500m at 9um ** ** PEG2BPFI-LX Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3 standard |
Optical Output Power: | Normal Mode ( Bypass Off): Typical: 6.8 dBm ( TX –Switch Norma – Fiber – LC/LC) Minimum: -10.9 dBm |
Optical Receive Sensitivity: | Normal Mode (Bypass Off) Typical: -18.9 dBm Maximum: -18.6 dBm |
Insertion Loss: | Bypass Mode: Insertion loss (Optical Power attenuation between TX to RX) Typical: 1.21 dB (From RX to TX) Maximum 1.9 dB |
Operating Systems Support | |
Operating system support: | Windows Linux FreeBSD VMware |
General Technical Specifications | |
Interface Standard: | PCI-Express Base Specification Revision 1.0 |
Board Size: | PCI Short add in card: 167.64mm x 68.91mm 6.6”X 2.713” |
PCI Express Card Type: | X4 |
PCI Express Voltage: | +3.3V ± 9%, +12V ± 8% |
PCI Connector: | Gold Finger: X4 |
Controller: | Intel 82571EB |
Holder: | Metal Bracket: Full Height and low profile, detailed description Appendix B |
Weight: | 110 gram (3.9 Oz) |
Power Consumption: | 3W, 0.01A at 12V and 0.86A at 3.3V: Typical all ports operate at 1000Mb/s. 2.6W, 0.01A at 12V and 0.75A at 3.3V: Typical No link at all ports. 2.6W, 0.01A at 12V and 0.75A at 3.3V:Bypass Mode. |
Operating Temperature: | 0°C – 50°C (32°F - 122°F) |
Storage: | -20°C–65°C (-4°F–149°F) |
EMC Certifications: | FCC Part 15, Subpart B Class B Conducted Emissions Radiated Emissions CE EN 55022: 1998 Class B Amendments A1: 2000; A2: 2003 Conducted Emissions Radiated Emissions CE EN 55024: 1998 Amendments A1: 2000; A2: 2003 Immunity for ITE Amendment A1: 2001 CE EN 61000-3-2 2000, Class A Harmonic Current Emissions CE EN 61000 3-3 1995, Amendment A1: 2001 Voltage Fluctuations and Flicker CE IEC 6100-4-2: 1995 ESD Air Discharge 8kV. Contact Discharge 4kV. CE IEC 6100-4-3:1995 Radiated Immunity (80-1000Mhz), 3V/m 80% A.M. by 1kHz CE IEC 6100-4-4:1995 EFT/B: Immunity to electrical fast transients 1kV Power Leads, 0.5Kv Signals Leads CE IEC 6100-4-5:1995 Immunity to conductive surges COM Mode; 2kV, Dif. Mode 1kV CE IEC 6100-4-6:1996 Conducted immunity (0.15-80 MHz) 3VRMS 80% A.M. By 1kHz CE IEC 6100-4-11:1994 Voltage Dips and Short Interruptions V reduc >95%, 30% >95% Duration 0.5per, 25per, 250per |
MTBF: | 99 (Years) *According to Telcordia SR-332 Issue 1 Environmental condition – GB (Ground, Fixed, Controlled). Ambient temperature - 25°C. Temperature rise of 15°C above the system ambient temperature was assumed for the cards components |
LEDs | |
LEDs: | (2) LEDs per port Link: Turns on link (yellow). ACT: Blinks on activity (green). (1) LED per Bypass pair: Bypass: Turns on Bypass (green) |
LEDs location: | LEDs are located on the PCB, visible via holes in the metal bracket holder |
Connectors: | (2) LC |
Functional Description
Silicom’s Dual Port Fiber Bypass adapter supports Normal, Bypass and Disconnect modes. In Normal mode, the ports are independent interfaces
(see Figure 1: Normal mode).
Figure 1: Normal Mode Functional Block Diagram
In Bypass mode, the connections of the Ethernet network ports are disconnected from the interfaces and switched over to the other port to create a crossed connection loop-back between the Ethernet ports. The connections of the interfaces are left unconnected. (See Figure 2)
Figure 2: Bypass Mode Functional Block Diagram
PEG2BPFI
Dual Port Fiber Gigabit Ethernet PCI Express Bypass Server Adapter Intel® Based
P/N | Description | Notes |
PEG2BPFI-SD-RoHS | Dual Port Fiber (SX) Gigabit Ethernet PCI Express Bypass Server Adapter | RoHS Compliant, 82571EB |
PEG2BPFI-LX-SD-RoHS | Dual Port Fiber (LX) Gigabit Ethernet PCI Express Bypass Server Adapter | RoHS Compliant, 82571EB |
Note: Model P/N -SD/-LP /-RoHS
-SD: Side Driver
-RoHS: RoHS Compliant / Lead free adapter
-LP: Assemble Low Profile Metal Bracket. Available only with Dual and Single ports adapters
1V1