Dual Port Fiber 10 Gigabit Ethernet PCI Express Bypass Server Adapter Intel® Based

This product has been discontinuedEOL Notification

Silicom’s dual port fiber 10igabit Ethernet Bypass server adapter is a PCI-Express X8 network interface card that contains two fiber (SR)10 Gigabit Ethernet ports on a PCI-E adapter. The

Silicom’s dual port copper 10 Gigabit Ethernet Bypass server adapter is targeted to inline network system that maintains network connectivity when system fails. Silicom’s dual port fiber 10 Gigabit Ethernet Bypass server adapter supports Normal , Bypass and Disconnect modes.

In Normal mode, the ports are independent interfaces. In Bypass mode, all packets received from one port are transmitted to the adjacent port. In Disconnect mode, the adapter simulates switch / rout cable disconnection. Silicom’s dual port fiber 10 Gigabit Ethernet Bypass server adapter can Bypass or Disconnect its Ethernet ports on a host system failure, power off, or upon software request.

In Bypass mode, the connections of the Ethernet ports are disconnected from the system and switched over to the other port to create a crossed connection loop-back between the Ethernet ports.

Hence, in bypass mode all packets received from one port are transmitted to the adjacent port and vice versa. This feature enables to bypass a failed system and provides maximum up time for the network.

Silicom’s dual port fiber 10 Gigabit Ethernet Bypass server adapter includes an on board WDT (Watch Dog Timer) controller. The adapter’s software drivers or software application can write commands to the on board WDT controller.

The adapter’s software drivers, WDT controller and the Bypass circuitry provide an interface that control and manage the mode of the adapter. Silicom’s dual port fiber 10 Gigabit Ethernet Bypass server adapter is based on Intel 82598 controller.

The Silicom’s 10 Gigabit Ethernet PCI Express Bypass Server adapter is the ideal solution for implementing multiple network segments, mission-critical high-powered networking applications and environments within high performance servers.

PE10G2BPI

Dual Port Fiber 10 Gigabit Ethernet PCI Express Bypass Server Adapter Intel® Based

Bypass / Disconnect:

  • Bypass / Disconnect Ethernet ports on Power Fail, System Hangs or Software Application Hangs
  • Software programmable Bypass, Disconnect or Normal Mode
  • On Board Watch Dog Timer (WDT) Controller
  • Software programmable time out interval
  • Software Programmable WDT Enable / Disable counter
  • Software programmable Bypass Capability Enable / Disable
  • Software Programmable Disconnect Capability Enable / Disable
  • Software Programmable mode (Bypass, Normal or Disconnect mode) at Power up
  • Software Programmable mode (Bypass, Normal mode) at Power off
  • Emulates standard NIC

Fiber 10Gigabit Ethernet 10GBase-SR:

  • Short Range Fiber 10Gigabit Ethernet channels support 10GBase-SR
  • LC connectors

Fiber 10 Gigabit Ethernet 10GBASE-LR:

  • 10 Gigabit Fiber Ethernet port supports 10GBASE-LR (1310nM LAN PHY)
  • LC connector

Common Key features:

  • Host Interface:
  • PCI Express X8 lane
  • Support PCI Express Base Specification Revision 2.0 / 2.5GHz5

Performance Features:

  • IPV6 Supports for IP/ TCP and IP/UDP Receive Checksum offload
  • Fragmented UDP checksum offload for Packet Reassembly
  • Receive Side Scaling minimize CPU utilization across multiple processor systems
  • Support for 16 virtual machine Device Queues ( VMDq) per port
  • Support Direct Cache Access ( DCA)
  • Advanced memory architecture reduces latency
  • Minimized device I/O intterupts using MSI and MSI-X
  • Offload of TCP / IP / UDP checksum calculation and TCP segmentation
  • Large on chip receive packet buffer (520 KB)

LAN Features:

  • IEEE 802.x flow control support
  • IEEE 802.q VLAN tagging support
  • IEEE 802.1p layer 2 priority encoding
  • Jumbo Frame (up to 16KB)
  • Link Aggregation and Load Balancing
  • RFC2819 RMON MIB statistics
  • TCP Segmentation Offload Up to 256KB
  • Ipv6 Support for IP/TCP Receive Checksum Offload
  • DDP Offload
  • LEDs indicator for link/Activity

PE10G2BPI

Dual Port Fiber 10 Gigabit Ethernet PCI Express Bypass Server Adapter Intel® Based

Bypass Specifications:

WDT Interval (Software Programmable): 3,276,800 mSec (3,276.8 Sec): Maximum
100 mSec ( 0.1 Sec) : Minimum
WDT Interval = (2^wdt_interval_parameter)*(0.1) sec.
wdt_interval_parameter: { Valid Range: 0-15}

Fiber Gigabit Ethernet Technical Specifications – (10Base-SR) Adapters:

IEEE Standard / Network topology: Fiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)
Data Transfer Rate: 20Gbit/s in full duplex mode per port
Cables and Operating distance:
Up to:
62.5um, 160MHz/Km 13m*
62.5um, (OM1)200MHz/Km 16m*
50um, 400MHz/Km 33m*
50um, (OM2)500 MHz/Km 41m*
50um, (OM3)2000MHz/Km 150m*
Defined as half a distance as stated by the IEEE 802.3 standard
Output Transmit Power: Typical: -2.6 dBm
Minimum: -3 dBm
Optical Receive Sensitivity: Typical: -14.6 dBm
Maximum: -11.1 dBm
Maximum Input Power: Maximum: +0.5dBm
Insertion Loss: Bypass Mode:
Insertion loss (Optical Power attenuation between TX to RX)
Typical: 1.0 dB (From RX to TX)
Maximum 1.9 dB

Fiber Gigabit Ethernet Technical Specifications – (10Base-LR) Adapters:

IEEE Standard / Network topology: Fiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)
Data Transfer Rate: 10.3125GBd
Cables and Operating distance:
Up to:
Single-Mode: 5000m at 9um*
Defined as half a distance as stated by the IEEE 802.3 standard
Output Transmit Power: Typical: -2.25 dBm
Minimum: +0.5dBm
Optical Receive Sensitivity: Typical: -19.5 dBm
Maximum: -12.6 dBm
Maximum Input Power: Maximum: +0.5dBm
Insertion Loss: Bypass Mode:
Insertion loss (Optical Power attenuation between TX to RX)
Typical: 1.0 dB (From RX to TX)
Maximum 1.6 dB

Operating Systems Support

Operating system support: Windows
Linux

General Technical Specifications

Interface Standard: PCI-Express Base Specification Revision 2.0 / 2.5GHz
Board Size: Standard height short PCI add in card
167.64mm X 111.15mm (6.60″X 4.376″)
PCI Express Card Type: X8 Lane
PCI Express Voltage: +3.3V +-9%,
+12V +- 8%
PCI Connector: X8 Lane
Controller:  Intel 82598
Holder: Metal Bracket
Weight: 270 gram (9.524 Oz)
Power Consumption: PE10G2BPI-SR
11.2 W, 0.59A at 12V and 1.24A at 3.3V: Typical, all ports operate at 10Gb/s.
11.0W, 0.59A at 12V and 1.18A at 3.3V: Typical, No link at all ports.
PE10G2BPI-LR
11.93 W, 0.59A at 12V and 1.47A at 3.3V: Typical, all ports operate at 10Gb/s.
11.68W, 0.58A at 12V and 1.43A at 3.3V: Typical, No link at all ports.
Operating Humidity: 0%–90%, non-condensing
Operating Temperature: 0°C – 50°C (32°F – 122°F)
Storage: -20°C–65°C (-4°F–149°F)
EMC Certifications: FCC Part 15, Subpart B Class B
Conducted Emissions
Radiated Emissions
CE EN 55022: 1998 Class B Amendments A1: 2000; A2: 2003
Conducted Emissions
Radiated Emissions
CE EN 55024: 1998 Amendments A1: 2000; A2: 2003
Immunity for ITE Amendment A1: 2001
CE EN 61000-3-2 2000, Class A
Harmonic Current Emissions
CE EN 61000 3-3 1995, Amendment A1: 2001
Voltage Fluctuations and Flicker
CE IEC 6100-4-2: 1995
ESD Air Discharge 8kV. Contact Discharge 4kV.
CE IEC 6100-4-3:1995
Radiated Immunity (80-1000Mhz), 3V/m 80% A.M. by 1kHz
CE IEC 6100-4-4:1995
EFT/B: Immunity to electrical fast transients 1kV Power
Leads, 0.5Kv Signals Leads
CE IEC 6100-4-5:1995
Immunity to conductive surges COM Mode; 2kV,
Dif. Mode 1kV
CE IEC 6100-4-6:1996
Conducted immunity (0.15-80 MHz) 3VRMS 80% A.M.
By 1kHz
CE IEC 6100-4-11:1994
Voltage Dips and Short Interruptions
V reduc >95%, 30% >95% Duration 0.5per, 25per, 250per
MTBF*: 58 (Years)
*According to Telcordia SR-332 Issue 1
Environmental condition – GB (Ground, Fixed, Controlled). Ambient temperature – 25°C. Temperature rise of 10°C above the system ambient temperature was assumed for the cards components

LEDs

LEDs: (2) LED per port
Link: Turns on link (green).
ACT: Blinks on activity (green).
Bi-color LED per Bypass pair:
BYPASS: Turns on Bypass ( green)
Disconnect : Turns on Disconnect ( yellow)
Normal: Off
LEDs location: LEDs are located on the PCB, visible via holes in the metal bracket holder
Connectors: LC

 

Functional Description

Silicom’s Bypass Server adapters support Normal, Bypass and Disconnect modes.

In Normal mode, the ports are independent interfaces (see Figure 1: Normal mode, one Bypass pair is illustrated).

Figure 1: Normal Mode Functional Block Diagram

Functional Block Diagram 1

In Bypass mode, the connections of the Ethernet network ports are Disconnected from the interfaces and switched over to the other port to create a crossed connection loop-back between the Ethernet ports. The connections of the interfaces are left not connected. (See Figure 2: one Bypass pair illustrated)

Figure 2: Bypass Mode Functional Block Diagram

Functional Block Diagram 2

In Disconnect mode, the transmit connections of the Ethernet network ports are Disconnected from the interfaces. (See Figure 3: one Bypass pair illustrated)

Figure 3: Disconnect Mode Functional Block Diagram

Functional Block Diagram 3

Silicom Bypass server adapters include an on board Controller that can Bypass the Ethernet ports on host system failure like Power Off, System hangs or software application hangs. The software programmable Watch Dog Timer (WDT) Controller detects a host system fails and it will Bypass automatically the Ethernet ports after programmable time out interval. The WDT Controller can be software programmable enabled or disabled.

Silicom Bypass server adapters support software programmable to select Bypass or Normal mode. In Normal mode, the ports of the adapters remain independently operational.

The drivers of the adapters and the Bypass circuitry provides an interface that control and management the mode of the adapter. The adapter software driver or software application can writes commands to the on board controller. The on board controller processes the commands and activates the bypass circuitry accordingly.

After power up the default mode of the adapter is to be in Bypass mode. After driver is loaded, the adapter software driver or application can set the card to a Normal mode. After the Host system issues reset, setting of Bypass controller and circuitry are reserved.

Silicom Bypass server adapters support Disable Bypass Capability; hence, if those adapters receive Disable Bypass Capability command, the adapter does not Bypass its Ethernet ports, in this state the four Ethernet ports are independent. The Disable Bypass Capability state is reserved also after power off. This feature enables to emulate a standard NIC.

Silicom Bypass server adapters can be set to Bypass or Normal mode at power up. This setting programmable and is reserved also after power off.

PE10G2BPI

Dual Port Fiber 10 Gigabit Ethernet PCI Express Bypass Server Adapter Intel® Based

P/N

Description

Notes

PE10G2BPI-SR-SD Dual port Fiber (SR) 10 Gigabit Ethernet PCI Express Bypass Server Adapter RoHS Compliant,
X8, based on Intel 82598, standard height card
PE10G2BPI-LR-SD Dual port Fiber (LR) 10 Gigabit Ethernet PCI Express Bypass Server Adapter RoHS Compliant,
X8, based on Intel 82598, standard height card

 

1V5