BSE-Series - Silicom Ethernet Managed Bypass Switch Specifications

description key features technical specifications order info

Silicom Managed Bypass Switch is designed for 10 / 1 Gigabit Ethernet networks. The Silicom managed Bypass switch is targeted to maintain network connectivity when the in-line system fails. The Managed Bypass switch is based on reliable a passive switch, console management port and on board watch dog timer controller.


Silicom Managed Bypass switch supports two modes of operations: Normal and Bypass. In Normal modes, the Bypass switch diverts the network traffic to attached in-line network system. In Bypass mode, the inline traffic is diverted to the network link and no longer routed to the in-line device. The Managed Bypass Switch can be programmed to Bypass its Ethernet ports on event of power fail, Link fail or user request.


The Silicom Managed Bypass switch includes an on board Watchdog timer controller (WDT) and a passive switch. The on board WDT controller can receive heartbeat “alive” packet via its serial communication console, USB, or its Ethernet port (selected models).

The Silicom Managed Bypass switch can be shipped as a stand alone unit (BSS) or as a rackmount 1U host system (BS1U). The rackmount 1U host system support up to four Bypass modules. Each Bypass module supports a Bypass segment. The Bypass modules in the 1U host system can be chained in order to enable multi-Bypass segment to support systems with limited management accessibility.

Stand Alone unit

TThe Silicom Managed Bypass switch a stand-alone flavor includes four 10 /1 Gigabit Ethernet data ports. Console management include Serial ( RJ11), USB and Ethernet port (selected models). The stand-alone flavor includes an external +12V power supply.

Figure: 1- Front panel view of BSSF-CEM



1U Rackmount host system

The 1U host system that supports up to four Bypass Switch modules. The Bypass switch host includes two redundant internal dual 110 – 220 V AC power supplies.

The Silicom Managed Bypass switch host supports two types of Bypass switch modules, a controller (-C) and a slave (-S). A controller Bypass switch (-C) module includes data ports and management ports. A slave module includes data ports only. A controller Bypass module ( -C) and a slave Bypass module can be chained 1U host system. The chain of modules was designed in order support systems with limited management accessibility that requires multi-Bypass segment configurations.

Figure: 2 - Front panel view of BS1U with four BSF-CEM

Key Features

Bypass Ethernet ports on Power Fail, System Hangs, management port fail, Software Application Hangs or user request

Software programmable Bypass or Normal Mode

On Board Watch Dog Timer (WDT) Controller

Software programmable time out interval

Software Programmable WDT Enable / Disable counter

Software programmable Bypass Capability Enable / Disable: Can be also in Normal mode at power off

Built-in Bypass circuitry, which operates in host system fails, Power OFF and programmable software

Programmable state (Bypass mode or Normal mode) at switch and host Power up, switch and host power off

Independent Bypass / Normal operation in every module

Reliable passive switch architecture

Chained configuration: enable multi-Bypass segment to support systems with limited management accessibility

 

10G / 1G Fiber Multi-mode

Supports Fiber Gigabit Ethernet (1000Base-SX)

Supports Short Range Fiber 10 Gigabit Ethernet (10GBase-SR)

 

10G / 1G Fiber Single - mode

Supports Fiber Gigabit Ethernet (1000Base-LX)

Supports Long Range Fiber 10 Gigabit Ethernet (10GBase-SR)

 

Bypass Switch 1U Host switch (BS1U)

Enable chaining modules – one console can control several slave modules in the system

1U mechanical specification

Dual internal 110 – 220V AC Power supply for redundancy

Multi-Mode: Fiber Gigabit Ethernet Technical Specifications - (10GBase-SR)

IEEE Standard / Network topology

Fiber Gigabit Ethernet, 10GBase-SR (850nM)

 

Data Transfer Rate

20Gbit/s in full duplex mode per port

Cables and Operating distance

Multimode fiber:62.5um
16.5m maximum at 62.5 um **
Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3 standard

Insertion loss (Normal)

Typical: 0.8 dB
Maximum: 1.9 dB

Insertion Loss (Bypass)

Typical: 0.8 dB
Maximum 1.9 dB

Fiber Gigabit Ethernet General Technical Specifications - (1000Base-SX)

IEEE Standard / Network topology

Fiber Gigabit Ethernet, 1000Base-SX (850nM)

 

Cables and Operating distance

Multimode fiber:
137m maximum at 62.5 um **
**Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3 standard

Insertion Loss (Normal Mode)

Typical: 0.8 dB
Maximum: 1.9 dB

Insertion Loss (Bypass Mode)

Typical: 0.8 dB
Maximum: 1.9 dB

Single-Mode: Fiber 10Gigabit Ethernet Technical Specifications - (10G Base-LR) Adapters

IEEE Standard / Network topology

Fiber Gigabit Ethernet, 10Base-LR (1310nM)

Data Transfer Rate

20Gbit/s in full duplex mode per port

Cables and Operating distance

Multimode fiber:9um
5000m maximum at 9 um **
Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3 standard

Insertion Loss (Normal Mode)

Typical: 1.2 dB
Maximum: 1.6 dB

Insertion Loss (Bypass Mode)

Typical: 1.2 dB
Maximum: 1.6 dB

Fiber Gigabit Ethernet Technical Specifications - (1000Base-LX) Adapters
IEEE Standard / Network topology

Fiber Gigabit Ethernet, 1000Base-LX (1310nM)

Data Transfer Rate 2000Mbit/s in full duplex mode per port
Cables and Operating distance

Single-Mode fiber: 9um
2500m maximum at 9um **
** Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3 standard

Insertion Loss (Normal Mode)

Typical: 1.2 dB
Maximum: 1.6 dB

Insertion Loss (Bypass Mode)

Typical: 1.2 dB
Maximum: 1.6 dB

Bypass Specification

WDT Interval (Software Programmable)

3,276,800 mSec (3,276.8 Sec): Maximum
100 mSec ( 0.1 Sec) : Minimum

WDT Interval = (2^wdt_interval_parameter)*(0.1) sec.
wdt_interval_parameter: { Valid Range: 0-15}

Bypass Switch stand alone : BSSF-CEM / -CES Stand alone, stand alone Controller Multi-Mode and Single Mode

Size

x 152mm x 120.5mm x 24mm (6" x 4.75" x 1")
Wide x Depth X Height

Voltage +12V (Min 11.4, Max, 12.6V)
Operating Humidity 0%–90%, non-condensing
Operating Temperature 0°C – 50°C (32°F - 122°F)
Storage Temperature -20°C–65°C (-4°F–149°F)
EMC Certifications Class B
MTBF* > 50 years

BSF : LED Connector Specifications

LEDs

(3) LEDs per
Power
Normal
Alarm

Connectors

(4) LC per segment
RJ11 console
USB console
RJ45 console

BS1U: Bypass Switch 1U Host system

Dockings

Front holders 1U rack mount

Voltage Input

AC: 90-240 VAC Auto-Select

Size

444mm x 270 mm x 44 mm ( 17.48” x 10.63” x 1.732”)
Wide x Depth X Height

Operating Humidity

0%–90%, non-condensing

Operating Temperature

0°C – 50°C (32°F - 122°F)

Storage Temperature

-20°C–65°C (-4°F–149°F)

EMC Certifications Class B
MTBF* > 50 years
BSF-CEM/ -CES 1U module Controller Multi-Mode and Single Mode

Size

129mm x 100mm (7.709" x 3.937")

Voltage

+12V (Min 11.4, Max, 12.6V)

Operating Humidity

0%–90%, non-condensing

Operating Temperature

0°C – 50°C (32°F - 122°F)

Storage Temperature

-20°C–65°C (-4°F–149°F)

EMC Certifications

Class B

MTBF* > 50 years

BSF-CEM/ -CES 1U: LED and Connector Specifications

LEDs (3 ) LED
Power
Normal
Alarm
Connectors (4) LC per segment
RJ11 console
USB console
RJ45 console

BSF-SEM/ -SES 1U module Slave Multi-Mode and Single Mode

Size

129mm x 100mm (7.709" x 3.937")

Voltage

+12V (Min 11.4, Max, 12.6V)

Operating Humidity 0%–90%, non-condensing
Operating Temperature 0°C – 50°C (32°F - 122°F)
Storage Temperature -20°C–65°C (-4°F–149°F)
EMC Certifications

Class B

MTBF* > 50 years

BSF-SEM/ -SES 1U Slave Module: LED and Connector Specifications

LEDs:

(3 ) LED
Power
Normal
Alarm

Connectors: (4) LC per segment

Functional Description

Figure: 3 - Normal Mode Functional Block Diagram
 


Figure: 4 - Bypass Mode Functional Block Diagram



P/N System Format Media Console Port Media Type -XY-XY-XY

Power Cord

-R

Managed Bypass Switch

1U: 1U
S: Stand Alone
F: Fiber
T: Copper
-SE: Slave

-CE: Controller w/Ethernet
M: Multimode

S: Single mode

T: Copper
For additional modules console port and media type:
X: C / S / CE

Y: M/S/T

-US
-EU
-CN
-48

ROHS


Stand Alone

P/Nm Description Notes
BSSF-CEM- US-R 10 /1 Gigabit (MM) Fiber Managed Bypass switch Stand alone, controller Multimode, w/ US style power cable, Ethernet, serial and USB management cables.
BSSF-CEM- EU-R 10 /1 Gigabit (MM) Fiber Bypass Managed Switch Stand alone, controller Multimode, w/ EU style power cable, Ethernet, serial and USB management cables
BSSF-CEM- CN-R 10 /1 Gigabit (MM) Fiber Bypass Managed Switch Stand alone, controller Multimode, w/ CN style power cable, Ethernet, serial and USB management cables.
BSSF-CES- US-R 10 /1 Gigabit (SM) Fiber Bypass Managed switch Stand alone, controller Singlemode, w/ US style power cable, Ethernet serial and USB management cables
BSSF-CES- EU-R 10 /1 Gigabit (SM) Fiber Managed Bypass Switch Stand alone, controller Singlemode, w/ EU style power cable, Ethernet, serial and USB management cables
RK-1U-2-BSS 1U Rack Mount Kit for two BSS products New Cell


1U Host System


P/N Description Notes
BS1U-CEM-US-R 1U w/ 10 /1 Gigabit (MM) Fiber Managed Bypass Switch 1U 1U host with one controller Multimode, w/ US style power cable, Ethernet, serial and USB management cables
BS1U-CEM-CN-R 1U w/ 10 /1 Gigabit (MM) Fiber Managed Bypass Switch 1U 1U host with one controller Multimode, w/ CN style power cable, Ethernet, serial and USB management cables
BS1U-CES-US-R 1U w/ 10 /1 Gigabit (SM) Fiber Managed Bypass Switch 1U 1U host with one controller Single mode, w/ US style power cable, Ethernet, serial and USB management cables
BS1U-CEM-SM-US-R 1U w/ Two 10 /1 Gigabit (MM) Fiber Managed Bypass Switch 1U host with one controller, one slave Multimode, w/ US style power cable, Ethernet, serial and USB management cables
BS1U-CES-SS-US-R 1U w/ Two 10 /1 Gigabit (SM) Fiber Managed Bypass Switch 1U host with one controller, one slave Single mode, w/ US style power cable, Ethernet, serial and USB management cables
BS1U-CEM-CM-EU-R 1U w/ Two 10 /1 Gigabit (MM) Fiber Bypass Switch 1U host with with two Multimode, controller w/ EU style power cable, Ethernet, serial and USB management cables
BS1U-US-RoHS Bypass Switch 1U Host System 1U host system w. US style power cable
BS1U-EU-RoHS Bypass Switch 1U Host System 1U host system w / EU style power cable
BS1U-CN-RoHS Bypass Switch 1U Host System 1U host system w / CN style power cable
BS1U-48-RoHS Bypass Switch 1U Host System 1U host system w / -48V redundant power supply
BSF-CEM-R 10/1 Gigabit (MM) Fiber Managed Bypass switch Add-in module, controller Multimode, w/, Ethernet serial and USB management cables
BSF-CES-R 10/1 Gigabit (SM) Fiber Managed Bypass switch Add-in module, controller single, w/ serial, Ethernet and USB management cables
BSF-SEM-R 10/1 Gigabit (MM) Fiber Managed Bypass switch Add-in module, slave Multimode, w/ serial, Ethernet and USB management cables.
BSF-SES-R 10/1 Gigabit (SM) Fiber Managed Bypass switch Add-in module, slave single, w/ serial, Ethernet and USB management cables

 

Note: Model P/N
--US: Includes US power cable (90-240 VAC Auto-Select)
-EU: Includes EU power cable (90-240 VAC Auto-Select)
-CN: Includes CN power cable (90-240 VAC Auto-Select)
-48: (-75 - -36) VDC